MPO To SC Adapter Cable

Send Inquiry
MPO To SC Adapter Cable
Details
MPO to SC Adapter Cable is a factory-terminated fiber optic fanout assembly that connects a high-density MPO/MTP® interface to individual SC optical interfaces. The assembly can be specified by fiber mode, fiber count, MPO gender, SC polish, polarity, cable jacket, overall length, and breakout-leg length to match the optical link and installation environment.
Category
MPO/MTP Adapter Cable
Share to
Description

MPO to SC Adapter Cable is a factory-terminated fiber optic fanout assembly that connects a high-density MPO/MTP® interface to individual SC optical interfaces. The assembly can be specified by fiber mode, fiber count, MPO gender, SC polish, polarity, cable jacket, overall length, and breakout-leg length to match the optical link and installation environment.

 

Configuration Options

 

Parameter

Available Options

Fiber Mode

OS2, OM3, OM4, OM5

Fiber Count

8F, 12F, 24F

MPO Performance

Standard Loss ≤0.70 dB; Low Loss ≤0.35 dB; Ultra Low Loss ≤0.20 dB

Cable Jacket

PVC, LSZH, OFNR, OFNP

Operating Temperature

-20°C to +70°C

Cable Structure

Round cable with breakout legs

Length

Custom overall and breakout-leg lengths

 

Connector & Gender Configuration

 

The MPO/MTP® end is available in male (pinned) or female (unpinned) configurations. The correct gender must match the mating MPO interface; pinned-to-pinned mating is not suitable for standard MPO connections.


The SC side is available with UPC or APC polish. SC connectors and MPO connectors can be supplied according to applicable interface standards, including IEC 61754-20 for SC and IEC 61754-7 / TIA-604-5 for MPO interfaces.

 

MPO Polarity Configuration

 

Type A, Type B, and Type C polarity configurations are available.


Type A: Maintains the same fiber position sequence between ends.


Type B: Reverses the fiber position sequence.


Type C: Reverses fiber pairs.


Polarity should be selected based on the complete end-to-end cabling architecture, including MPO trunks, cassettes, transceivers, and patching components.

 

Fiber Count & Cable Construction

 

Available configurations include 8-fiber, 12-fiber, and 24-fiber assemblies for OS2 single-mode or OM3/OM4/OM5 multimode applications. Standard breakout construction uses a main MPO cable that transitions into individual SC legs, with cable and leg dimensions configured according to the required assembly.


LSZH is available for low-smoke, halogen-free installations, while OFNR/OFNP options can be specified for North American riser or plenum applications. Cable colors can also follow common fiber-industry conventions for OS2 and multimode fiber.

 

Applications

Data Center Cabling

Connects MPO backbone or trunk cabling with SC-based equipment and patching systems.

Telecom Infrastructure

Interfaces high-density MPO distribution with SC optical distribution frames and related equipment.

Network Upgrades

Provides an interface between newly deployed MPO infrastructure and existing SC-based systems.

Structured Fiber Cabling

Supports pre-terminated, organized connections where individual SC interfaces are required.

 

Customization & OEM

 

OEM configurations can be produced according to project requirements, including fiber count, fiber type, MPO gender, SC UPC/APC, polarity, cable jacket, overall length, breakout-leg length, cable diameter, labeling, and private packaging.


Custom and bulk OEM orders can be scheduled according to the confirmed specification and production requirements.

 

Testing & Quality Control

 

Each assembly is subject to optical and mechanical quality checks before shipment. Quality control can include:

  • 100% Insertion Loss (IL) and Return Loss (RL) testing
  • 3D interferometer inspection of MPO ferrule geometry
  • Connector end-face inspection
  • Mechanical pull and connector durability testing
  • Individual test data for shipment traceability

Test requirements and acceptance limits are established according to the ordered fiber type, connector configuration, and selected loss grade.

 

FAQ

 

Q: Can you produce cables according to an existing sample?

A: Yes. Sample-based OEM production can be supported. The supplied sample, drawing, or reference assembly can be used to confirm connector configuration, cable dimensions, breakout structure, labeling, and other production details before bulk manufacturing.

Q: What is the typical MOQ for MPO to SC Adapter Cables?

A: For standard configurations, a low-volume trial order can typically be accepted, while OEM production is normally quoted according to quantity and customization requirements. For distributor or project orders, the MOQ and unit price should be confirmed based on the final specification.

Q: What is the typical production lead time?

A: Standard custom OEM orders are fulfilled within 7–12 working days after the specifications and order are confirmed. The production schedule is based on the confirmed configuration and order quantity.

Q: How can I ensure the cable matches my existing MPO infrastructure?

A: Provide the mating connector specification and the complete link configuration, especially the MPO key orientation, pin configuration, polarity, and fiber mapping.

Q: Are replacement or repeat orders manufactured to the same specification?

A: Yes. Repeat orders can be manufactured against an approved specification, drawing, sample, or previously confirmed part number.

Q: What shipping terms are available for international orders?

A: Shipping can be arranged under terms such as EXW, DDP, or DAP, depending on the destination, order quantity, and agreed commercial terms.

Hot Tags: MPO to sc adapter cable, China MPO to sc adapter cable manufacturers, suppliers, factory

Send Inquiry