MPO/MTP Trunk Cable
Pre-terminated MPO/MTP trunk assemblies for high-density fiber distribution, configured by fiber count, connector arrangement, gender, polarity, fiber type, trunk length, breakout length, optical loss, and cable construction.
DIMI supplies standard and project-specific trunk configurations based on cable schedules, connection layouts, and specified interface requirements.
-
High Density MPO Trunk CableDIMI Fiber High Density MPO Trunk Cable is a pre-terminated fiber optic cabling solution designed for modern data centers, cloud computing facilities, and high-speed optical networks.
-
OS2 MPO Trunk CableDIMI OS2 MPO Trunk Cable is a factory-terminated multi-fiber assembly using OS2 single-mode fiber and MPO connectors to consolidate multiple optical channels into a single pre-terminated trunk...
-
OM4 MPO Trunk CableDIMI OM4 MPO Trunk Cable is a factory-terminated multimode fiber assembly using OM4 50/125 μm fiber and MPO connectors at both ends. It provides a pre-terminated MPO-to-MPO multi-fiber connection...
-
48 Fiber MPO Trunk CableThe 48 Fiber MPO Trunk Cable is a factory-terminated 48-fiber optical trunk assembly with MPO/MTP connectors at both ends, designed for high-density multi-fiber connections between compatible...
-
12 Fiber MPO Trunk CableDimiFiber's 12 Fiber MPO Trunk Cable is a factory-terminated fiber optic assembly containing 12 optical fibers and MPO/MTP connectors at the cable ends.
MPO/MTP Trunk Cable Configurations
|
Parameter |
Available Configurations |
|
Fiber Count |
8F, 12F, 16F, 24F and project-specific counts |
|
Fiber Type |
Multimode or single-mode |
|
Connector |
MPO/MTP configurations |
|
Gender |
Male, female, or specified combination |
|
Polarity |
Type A, Type B, Type C, or specified mapping |
|
Cable Length |
Project-specific |
|
Breakout Length |
Project-specific |
|
Optical Loss |
Standard or low-loss |
|
Jacket |
LSZH, OFNR, OFNP and specified options |
|
Construction |
Standard, reinforced or project-specific |
|
Identification |
Cable marking and labeling |
The final configuration is established from the cable schedule or connection layout.
Fiber Count Options
|
Fiber Count |
Cable Structure |
Typical Matching |
Typical Use |
|
8F / 16F |
Base-8, 8F subunits |
Base-8 MPO/MTP systems |
High-density optical links |
|
12F / 24F |
Base-12, 12F subunits |
MPO/MTP cassettes and patch panels |
Standard backbone cabling |
|
48F / 72F |
Multi-subunit |
High-density racks and distribution frames |
Higher-capacity backbone runs |
|
96F–144F+ |
Multi-subunit / ribbon construction |
Large-scale fiber distribution |
High-capacity backbone infrastructure |
Connector Configuration Comparison
The two ends of an MPO/MTP trunk do not always need to use the same connector configuration. .
|
Configuration |
Typical Requirement |
|
MPO/MTP → MPO/MTP |
Direct connection between compatible multi-fiber interfaces |
|
Different connector types |
Connection between different interface types or distribution points |
|
Different end configurations |
Used when Connector A and Connector B require different gender, polish, or interface specifications |
Connector selection should include the connector type, interface, gender, polish, and end-specific configuration where applicable.
Polarity Comparison
|
Polarity |
Fiber Mapping |
|
Type A |
Straight-through mapping |
|
Type B |
Reversed mapping |
|
Type C |
Pair-wise reversal |
The polarity of the trunk must work with the polarity of the connected adapters, cassettes, patching components, and optical equipment.
Cable Length & Breakout Length
|
Parameter |
Defines |
Selection Consideration |
|
Overall Trunk Length |
Main trunk section |
Matches the distance between connection points |
|
Breakout / Leg Length |
Length from breakout to connector |
Matches equipment and panel reach |
|
End-Specific Leg Length |
Different leg lengths at each end |
Used for asymmetric rack layouts |
Cable Construction & Jacket Options
|
Configuration |
Selection Consideration |
|
Standard |
Compact construction for controlled routing environments |
|
Reinforced |
Additional mechanical protection |
|
Armored |
Higher protection for demanding installation environments |
|
LSZH / OFNR / OFNP |
Select according to installation and fire-rating requirements. |

DIMI checks MPO/MTP trunk assemblies through connector inspection, optical testing, polarity verification, and mechanical inspection before shipment. Test scope and documentation can be specified according to project requirements.
Connector Inspection: End-face and connector geometry are inspected against applicable specifications.
Optical Testing: Insertion loss, return loss, continuity, and OTDR testing are available according to product and project requirements.
Polarity Verification: Fiber mapping is checked against the specified polarity and connector configuration.
Assembly Inspection: Breakout areas, connector attachment, cable routing, and overall assembly condition are inspected before packing.
Traceability: Production and inspection records can be maintained for specified project orders.
Why Source MPO/MTP Trunk Cables from DIMI
50,000+ m² Manufacturing Operations
Dedicated production areas for fiber optic cable, connector assembly, hardware manufacturing, and final testing, supported by controlled manufacturing environments.
Automated Fiber Optic Production
Automated fiber cutting, connector assembly, precision polishing, epoxy curing, and computer-controlled processing support consistent production across standard and project-specific assemblies.
50+ Engineers & Technical Personnel
A multidisciplinary engineering team supports product development, manufacturing process improvement, and project-specific fiber optic configurations.
Scalable Production Capacity
Annual capacity exceeds 2 million connector assemblies and 500,000 meters of fiber optic cable, with production systems structured for both volume orders and varied project specifications.
FAQ
As one of the most professional MPO/MTP trunk cable manufacturers and suppliers in China, our products have good reputation in the market. Please rest assured to wholesale advanced MPO/MTP trunk cable made in China here from our factory. Also, custom service is available.