MPO/MTP Multimode Fiber Cable

 

MPO/MTP multimode fiber cables for short- and medium-reach, high-density optical connectivity in data centers and high-speed network systems. Available with OM3, OM4, and OM5 50/125 μm multimode fiber, Base-8 or Base-12 configurations, multiple fiber counts, connector genders, polarity types, and optical loss options.


The cable configuration is selected according to the transceiver interface, transmission speed, link distance, fiber grade, fiber count, polarity, and required optical performance.

 

 
  • High Density MPO Multimode Fiber Cable
    The High Density MPO Multimode Fiber Cable is a pre-terminated multi-fiber cable assembly designed to consolidate multiple multimode optical channels through MPO/MTP-compatible connector interfaces.
  • MPO To LC Multimode Fiber Cable
    The MPO to LC Multimode Fiber Cable is a pre-terminated breakout cable that connects a multi-fiber MPO/MTP interface with individual LC duplex connections in multimode fiber networks. It is used...
  • MPO Multimode Trunk Cable
    The MPO Multimode Trunk Cable is a high-density fiber assembly designed for structured cabling in data centers, enterprise server rooms, and high-speed network environments.
  • OM5 MPO Multimode Fiber Cable
    The OM5 MPO Multimode Fiber Cable is a pre-terminated high-density fiber assembly using OM5 wideband multimode fiber (WBMMF) and MPO connectors. It is designed for short-reach, high-bandwidth...
  • OM4 MPO Multimode Fiber Cable
    The OM4 MPO Multimode Fiber Cable is a factory-terminated, high-density fiber assembly for structured cabling in data centers, enterprise networks, and short-reach high-speed optical links. Using...
  • OM3 MPO Multimode Fiber Cable
    The OM3 MPO Multimode Fiber Cable is a factory-terminated multimode fiber assembly built with OM3 optical fiber and MPO/MTP multi-fiber connectors.
 
MPO/MTP Multimode Fiber Cable Specifications

Parameter

Available Options

Fiber Type

OM3 / OM4 / OM5

Fiber Size

50/125 μm

Wavelength

850 / 1300 nm

Connector

MPO / MTP

Gender

Male / Female

Polarity

Type A / Type B / Type C

Fiber Count

8 / 12 / 24 / 48 / 72 / 144

Cable Type

Round / Micro-distribution / Ribbon

Jacket

LSZH / PVC / OFNP

Operating Temperature

-20°C to +70°C

Testing

IL / RL / 3D Interferometry / End-Face Inspection

Compliance Options

RoHS / REACH / CE / UL / CPR, where applicable

Actual available configurations and compliance markings depend on the selected cable construction and project requirements.

 

OM3, OM4 & OM5 Multimode Fiber Options

Our MPO/MTP multimode fiber cables use 50/125 μm multimode fiber and are available in OM3, OM4, and OM5 grades for different high-speed network architectures.

Fiber Type

Typical Use

Key Consideration

OM3

10G/40G/100G short-reach links

Cost-effective multimode option for established data center networks

OM4

40G/100G and higher-speed data center links

Higher bandwidth and longer supported reach than OM3

OM5

High-speed multimode and SWDM applications

Wideband multimode fiber for multi-wavelength transmission

Actual transmission distance depends on the transceiver, transmission rate, optical link budget, and applicable network standard. We can review the complete configuration before production.

 

MPO To LC Multimode Fiber Cable

 

Base-8 & Base-12 MPO/MTP Configurations

MPO/MTP multimode assemblies can be configured for different high-density fiber architectures, including Base-8 and Base-12 systems.


Base-8: 8-fiber transmission architecture commonly used with parallel-optics applications and high-speed data center connectivity.


Base-12: 12-fiber configuration widely used in structured cabling and high-density backbone systems.

 

 

MPO/MTP Connector, Gender & Polarity

We supply MPO/MTP assemblies with different connector configurations to match the requirements of the complete link.


Connector Gender


Male: Connector with guide pins


Female: Connector without guide pins


The required gender depends on the mating equipment, cassette, adapter, trunk, or patching architecture.

High Density MPO Multimode Fiber Cable

 

Polarity

Available polarity configurations include:

Type A: Straight-through fiber mapping

Type B: Reversed fiber mapping

Type C: Pair-flipped fiber mapping

Polarity should be specified together with the transceiver and mating components to ensure correct transmit/receive fiber routing. 

 

Cable Construction & Jacket Options
 

MPO/MTP multimode assemblies are available in different cable constructions and jacket options for high-density data center cabling and installation requirements.

Round Cable

General-purpose construction for trunk and patching applications

Micro-Distribution Cable

Smaller cable profile for high-density routing and space-constrained installations

Ribbon Cable

Multi-fiber ribbon construction for high-count assemblies

LSZH

Low-smoke, halogen-free jacket option for installations with specific safety requirements

PVC

Standard jacket option for applicable indoor installations

OFNP

Plenum-rated construction for installations requiring OFNP cable performance

Cable length, fiber count, cable diameter, jacket type, and other construction details are selected according to the required MPO/MTP assembly configuration.

 

Standard-Loss & Low-Loss Options

MPO/MTP multimode fiber cables are offered in standard-loss and low-loss versions, allowing different connector loss requirements to be matched to the optical link budget.

Configuration

Typical Use

Standard-Loss

General data center and high-density multimode fiber links

Low-Loss

High-speed links where connector insertion loss has a tighter impact on the total link budget

Optical parameters: Insertion Loss (IL), Return Loss (RL), fiber attenuation, and connector end-face geometry.
Low-loss assemblies are available with selected MPO/MTP connector configurations and fiber types. The specified IL/RL limits are confirmed according to the cable configuration and project requirements.

 

OM4 MPO Multimode Fiber Cable

 

Applications

MPO/MTP multimode fiber cables are primarily used for high-density short-reach optical connectivity, including:

  • Enterprise data centers
  • Cloud computing facilities
  • High-performance computing (HPC) environments
  • Server and switch interconnections
  • High-density structured cabling
  • Data center backbone and distribution links

The cable configuration is selected according to the optical modules, rack architecture, fiber count, and required transmission distance.

 

 

Manufacturing Capabilities

DIMI Fiber manufactures MPO/MTP multimode fiber cables and fiber optic cable assemblies through integrated connector assembly, precision fiber termination, cable processing, optical testing, and final inspection. Our production capabilities support standard MPO/MTP configurations as well as project-specific multimode fiber cable assemblies.

  • Automated and precision-assisted fiber preparation, cleaving, polishing, and connector assembly
  • Controlled epoxy curing for connector termination
  • Cable jacketing and cable construction for different installation requirements
  • Production support for multi-fiber assemblies and different MPO/MTP configurations
OM5 MPO Multimode Fiber Cable

 

Optical Inspection & Testing

Each finished MPO/MTP assembly can be tested according to the ordered configuration before shipment.

Test / Inspection

Purpose

Buyer Evidence

Insertion Loss Testing

Verify optical loss of the connectorized assembly

IL test result

Return Loss Testing

Check optical reflection performance

RL test result

3D Interferometry

Verify MPO/MTP end-face geometry

Geometry inspection record

End-Face Inspection

Detect contamination, scratches, chips, and other defects

Inspection result

Polarity / Fiber Mapping

Verify fiber sequence and polarity

Fiber mapping record

Final QC Inspection

Confirm cable configuration against the order

Final inspection record

Test reports and inspection records can be supplied according to project requirements.

 

Custom MPO/MTP Multimode Fiber Cable Manufacturing
 

We manufacture MPO/MTP multimode cable assemblies according to drawings, BOMs, samples, or technical specifications.
Customization can include:

OM3 / OM4 / OM5 fiber
8–144 fiber configurations
Cable length
Connector type and gender
Type A / B / C polarity

Cable construction and jacket material
Pulling-eye kits
Jacket color
Product labeling and barcode
Individual test reports

For project orders, customers can provide the transceiver model, existing cable specification, system drawing, or BOM for configuration review before production.

 

 

FAQ

 

Q: Can you provide samples before a production order?

A: Yes. Sample orders can be arranged to verify connector fit, cable construction, fiber configuration, optical performance, and compatibility with the customer's existing equipment before a larger production order.

Q: What information do you need to quote MPO/MTP multimode fiber cables?

A: A basic quotation normally requires the required quantity, cable length, fiber configuration, connector configuration, and cable construction. For project-specific orders, providing the transceiver model, BOM, drawing, or existing cable sample allows us to review the configuration more accurately.

Q: Can you match an existing MPO/MTP cable?

A: Yes. An existing cable, product label, drawing, or sample can be used as a reference for reproduction. We can review the connector configuration, fiber mapping, cable construction, dimensions, and other identifiable specifications before confirming production.

Q: Can individual cables be labeled and traceable?

A: Yes. Product labels, part numbers, barcodes, serial numbers, and other identification requirements can be incorporated into the cable assembly where required. Test records can also be associated with the specified product identification.

Q: How are MPO/MTP cable assemblies packaged for international shipment?

A: Packaging can be configured according to cable length, fiber count, connector protection requirements, and shipping method. Connector end faces are protected during packing to reduce the risk of contamination or mechanical damage during transportation.

Q: Can you supply cables according to our BOM or project specification?

A: Yes. BOM-based production is available for project orders. The supplied specification can be reviewed before production to confirm the required cable configuration, quantities, labeling, and other purchasing requirements.

Q: What is the typical lead time for MPO/MTP cable orders?

A: Lead time depends on the cable configuration, fiber count, connector type, quantity, testing requirements, and current production schedule. The confirmed lead time is provided after the technical configuration and order quantity are reviewed.

Q: Can you provide documentation with the shipment?

A: Documentation can be supplied according to the order requirements, including product specifications, optical test results, inspection records, packing information, and other agreed quality documents.

As one of the most professional MPO/MTP multimode fiber cable manufacturers and suppliers in China, our products have good reputation in the market. Please rest assured to wholesale advanced MPO/MTP multimode fiber cable made in China here from our factory. Also, custom service is available.

Send Inquiry