High Density MPO Trunk Cable

Send Inquiry
High Density MPO Trunk Cable
Details
DIMI Fiber High Density MPO Trunk Cable is a pre-terminated fiber optic cabling solution designed for modern data centers, cloud computing facilities, and high-speed optical networks.
Category
MPO/MTP Trunk Cable
Share to
Description

The High Density MPO Trunk Cable is a factory-terminated multi-fiber optical cable assembly that consolidates multiple fibers into MPO/MTP trunk connections for high-count fiber interconnections.

 

Technical Specifications

 

Parameter

Specification

Product Type

High Density MPO Trunk Cable

Fiber Count

8F / 12F / 24F / 48F / 72F / 96F / 144F

Fiber Type

OS2 / OM3 / OM4 / OM5

Connector

MPO / MTP

Connector Configuration

MPO to MPO

Connector Gender

Male / Female

Polarity

Type A / Type B / Type C

Fiber Mapping

According to confirmed polarity and assembly configuration

Cable Structure

Micro Distribution / Ribbon / Customized

Cable Diameter

According to fiber count and cable construction

Minimum Bend Radius

10× Cable Diameter (loaded) / 20× Cable Diameter (unloaded)

Insertion Loss

≤0.35 dB Standard Loss / ≤0.20 dB Low Loss

Return Loss

SM ≥35 dB / MM ≥25 dB

Jacket

LSZH / OFNP / OFNR / PVC

Operating Temperature

-20°C to +70°C

Cable Length

Customized

Breakout

Customized

Pulling Eye

Available by configuration

Testing

100% Insertion Loss / Return Loss Testing

Inspection

3D End-Face Inspection

Polarity Verification

Yes

Test Documentation

Available by order requirement

Serialization

Available by order requirement

 

High-Density MPO Trunk Design

 

One Assembly
Multiple fibers are consolidated into a factory-terminated MPO/MTP assembly, reducing the number of separate trunk connections required for the same fiber path.


High-Count Configuration
Higher fiber counts require the trunk structure, breakout arrangement and connector configuration to be defined together before production.

 

MPO Configuration

Polarity

Type A, Type B and Type C configurations define the fiber-position relationship between the two MPO/MTP ends and must match the polarity architecture of the connected cabling system.

Connector Gender

Male or Female MPO/MTP connectors are specified according to the mating interfaces required at each end of the trunk.

Configuration Check

The specified polarity, connector gender and fiber mapping are checked against the confirmed production configuration before shipment.

 

Cable Construction

 

Cable Structure: Micro Distribution and Ribbon constructions organize high-fiber-count assemblies differently and can be selected according to the required routing and breakout arrangement.


Breakout: Breakout length and arrangement can be defined according to the connection layout between the trunk assembly and the equipment or distribution panel.


Pulling Eye: A pulling eye can be incorporated when the installation specification requires a defined pulling method for the pre-terminated trunk.


Jacket: LSZH, OFNP, OFNR and PVC jacket options can be specified according to the installation environment and project requirements.

 

Optical Performance

 

Loss Selection: The required loss grade should be selected according to the optical loss budget allocated to the complete channel.


Complete Channel: MPO adapters, cassettes, patch cords and other passive connections may contribute to the total channel loss and should be included in the project loss calculation.


Order Verification: The selected fiber type and optical requirements should be confirmed together with the connected equipment and planned channel configuration before production.

 

Factory Testing & Traceability

 

100% Optical Testing: Every finished High Density MPO Trunk Cable undergoes 100% insertion loss and return loss testing before shipment against the optical requirements confirmed for the order.


3D End-Face Inspection: MPO/MTP connector end faces undergo 3D interferometric inspection to verify the finished connector condition before shipment.


Configuration Verification: The completed assembly is checked against the confirmed production specification, including connector configuration, connector gender, polarity and fiber mapping where specified. Polarity and continuity verification are performed as part of the assembly check.


Test Documentation: Individual test reports can be provided with shipment when required for incoming inspection, project documentation or quality traceability.


Assembly Identification: Serialization or other assembly identification can be provided when specified, allowing the finished cable to be associated with its corresponding production and test records.

 

Standards & Compliance

 
 

MPO Interface

MPO/MTP connector assemblies can be manufactured with reference to IEC 61754-7 and TIA-604-5 interface requirements.

 
 
 

Structured Cabling

The cable assembly can be specified for structured optical fiber cabling projects referencing TIA-568.3-D requirements.

 
 
 

Market Requirements

RoHS, REACH and CE requirements can be addressed according to the specified product configuration and applicable market requirements.

 

 

FAQ

 

Q: What is the MOQ for High Density MPO Trunk Cable?

A: The MOQ is 500 pcs per specification. Project-specific quantities can be confirmed based on the fiber count, connector configuration and customization requirements.

Q: Can I order a sample High Density MPO Trunk Cable before bulk production?

A: Yes. A sample can be produced for specification and compatibility evaluation before bulk production. The sample can match the intended fiber count, connector configuration and polarity.

Q: What is the lead time for High Density MPO Trunk Cable?

A: Lead time depends on the fiber count, cable structure, connector configuration, customization requirements and order quantity. The confirmed lead time is provided after specification review.

Q: How is High Density MPO Trunk Cable pricing calculated?

A: Pricing is based on the confirmed cable configuration and order quantity, including fiber count, fiber type, connector configuration, polarity, cable structure, loss grade, length and breakout requirements.

Q: What payment terms are available for High Density MPO Trunk Cable orders?

A: Payment terms are confirmed according to the order value, project requirements and agreed commercial terms. The payment method and schedule are stated in the quotation or proforma invoice.

Q: Can High Density MPO Trunk Cable be manufactured from a customer BOM?

A: Yes. A customer BOM, cable schedule or technical specification can be reviewed to confirm the required fiber count, fiber type, connector configuration, polarity, fiber mapping, cable structure and length.

Q: What MPO polarity information should I provide when ordering?

A: Provide the required polarity together with connector gender, fiber mapping and the mating MPO/MTP interfaces. A BOM, cable drawing or existing polarity specification can also be used for configuration review.

Q: Can High Density MPO Trunk Cable be supplied in custom lengths and breakout configurations?

A: Yes. Cable length, breakout length and breakout arrangement can be specified according to the equipment, distribution panel and installation layout.

Q: What information should be included in an RFQ for High Density MPO Trunk Cable?

A: An RFQ should include fiber count, fiber type, connector configuration, connector gender, polarity or fiber mapping, cable structure, cable length, breakout, loss grade and jacket requirements. A BOM or cable drawing can also be provided.

Q: Can I receive an individual test report for a High Density MPO Trunk Cable?

A: Yes. Individual test reports can be provided with shipment when required, including the specified optical test records for incoming inspection and project documentation.

Hot Tags: high density MPO trunk cable, China high density MPO trunk cable manufacturers, suppliers, factory

Send Inquiry